2025 TITLE 24, PART 6 · ECC FIELD VERIFICATION & DIAGNOSTIC TESTING
HERS ECC Title 24 GroupSchedule a test

Complete services & measure catalog

More than a duct test.

Our ECC/HERS services follow the measures identified on the approved 2025 Title 24, Part 6 compliance documents. The exact verification required depends on occupancy, project scope, compliance approach, equipment, and the registered project documents.

Mechanical & HVAC

Space-conditioning verification

Diagnostic and visual measures for ducts, airflow, fans, refrigerant, equipment, filters, and specialized HVAC systems.

CF3R-MCH-20-H ↗

Duct leakage diagnostic test

Measures leakage from the duct system using calibrated test equipment for applicable new and existing systems.

CF3R-MCH-21-H ↗

Duct location verification

Verifies applicable duct location requirements or compliance credit conditions.

CF3R-MCH-22-H ↗

Fan efficacy

Measures electrical power used by the air-handler fan in relation to delivered airflow.

CF3R-MCH-23-H ↗

System airflow rate

Measures airflow through the space-conditioning system using an approved diagnostic procedure.

CF3R-MCH-24-H ↗

Building air leakage worksheet

Applicable mechanical documentation connected to building or dwelling-unit enclosure air-leakage testing.

CF3R-MCH-25-H ↗

Refrigerant charge verification

Verifies refrigerant charge using the applicable procedure and operating conditions for eligible cooling equipment.

CF3R-MCH-26-H ↗

Rated equipment verification

Confirms installed space-conditioning equipment matches the rated equipment and approved compliance documents.

CF3R-MCH-28-H ↗

Return duct & filter sizing

Verifies return-duct design and air-filter device sizing under the applicable Part 6 tables.

CF3R-MCH-29-H ↗

Duct surface area, R-value & buried ducts

Verifies conditions used for applicable duct-area reduction, insulation, or buried-duct compliance credit.

CF3R-MCH-30-H ↗

Central fan ventilation cooling

Verifies applicable Central Fan Ventilation Cooling System components and performance.

CF3R-MCH-31-H ↗

Whole-house fan airflow & efficacy

Measures whole-house fan airflow and fan efficacy where this measure is required.

CF3R-MCH-33-H ↗

Variable-capacity heat pump

Verifies eligible variable-capacity heat-pump equipment and applicable compliance-credit conditions.

Ventilation & exhaust

Indoor air quality and local exhaust

Verification of whole-building ventilation and local exhaust systems, including kitchen range hoods.

CF3R-MCH-27-H ↗

Indoor air quality & mechanical ventilation

Verifies required whole-building ventilation equipment, controls, and delivered airflow.

CF3R-MCH-32-H ↗

Kitchen range-hood verification

Measures or verifies local mechanical exhaust airflow and applicable sound/label information for kitchen range hoods.

CF3R-MCH-32-H ↗

Bathroom & local exhaust

Verifies applicable local mechanical exhaust fans serving bathrooms and other required spaces.

Airflow diagnostic ↗

Installed exhaust airflow

Uses approved airflow-measurement methods and confirms the installed system is accessible and operational.

Envelope & insulation

Building enclosure and QII

Field verification for air leakage, insulation quality, and existing conditions at the required construction stage.

CF3R-ENV-20-H ↗

Blower-door / building air leakage

Measures air leakage through building or dwelling-unit enclosures with calibrated blower-door equipment.

CF3R-ENV-21-H ↗

QII air sealing — framing stage

Verifies air-infiltration sealing before insulation and assemblies conceal required inspection areas.

CF3R-ENV-22-H ↗

QII insulation installation

Verifies insulation is installed without significant gaps, voids, compression, or misalignment.

CF3R-EXC-20-H ↗

Existing conditions verification

Verifies applicable existing building features used for an alteration compliance approach.

Water heating

Verified distribution measures

CF3R-PLB-22-H ↗

Hot-water distribution

Verifies eligible single-dwelling-unit hot-water distribution measures where specified by the compliance documents.

Documentation & project support

Keeping the compliance path organized

CHEERS registry support

Project review, applicable verification-document workflow, and coordination with the responsible parties.

CalCERTS-to-CHEERS assistance

Review of legacy records and available documents to determine the next registry and compliance steps.

Permit closeout review

Review of available permit and compliance information to identify field-verification work within our scope.

Contractor program support

Repeat scheduling, organized intake, field coordination, and consistent status communication for contractor partners.

Pre-cover coordination

Scheduling for QII, air sealing, ducts, and other measures that must be observed before construction covers the work.

Retesting

Focused retesting of measures after the responsible installer completes corrections.

Not every project requires every measure.

The registered compliance documents—not a generic website list—determine which verification forms and procedures apply to a particular project.

Measure names and form identifiers are based on the California Energy Commission’s 2025 Single-Family compliance-document library.

Send the project documents

We’ll confirm the applicable verification scope.

Include the address, permit number, scope, CF1R documents, installer information, and project stage.